E25: Sequencing on the Go
Designed for ultimate convenience, the E25 puts advanced sequencing power at your fingertips—anytime, anywhere. This ultra-portable system enables true on-the-go sequencing, with no need for bulky lab equipment or external computing.
Featuring a microfluidic flow cell, integrated CMOS detection, and self-luminous dye chemistry, the E25 delivers reliable results in a compact design. Its built-in computing module handles everything from sequencing to report generation—no extra hardware needed.
Other Material
Product Overview
Performance Parameters
| Supports MGI and App-C libraries and requires no primer substitutions | ||||
|---|---|---|---|---|
| Effective Reads* | Read Length** | Data Output | Run Time*** | Q30**** |
| 25 M | SE100 | 2.5 GB | ~5 h | >90% |
| 25 M | PE150 | 7.5 GB | ~20 h | >80% |
| 20 M | App-C SE100 | 2.0 Gb | ~5 h | >90% |
| 20 M | App-C PE150 | 6.0 Gb | ~20 h | >80% |
| * The effective reads value is obtained according to the operation of a specific standard library, and the actual application library will fluctuate according to the sample type and library construction method. ** The existing kit supports SE50 and PE100 reads, and the instrument does not have SE50 and PE100 sequencing modes. *** Run time includes DNB loading and FASTQ generation. Barcode sequencing time is excluded. **** The percentage of bases above Q30 and the running time are averaged over the entire run for a particular standard library. The practical application performance is affected by sample type, library quality, insert length and other factors. | ||||
Applications
| Study Subject | Methodology | Applications | Recommended Read length | Recommended data size | FCL Recommended samples/RUN |
|---|---|---|---|---|---|
| Microorganism Genome | Target Sequencing | ATOPlex panel | SE100 | COVID-19:~1M reads/sample | 24sample |
| SE100/PE150 | Monkeypox SE100:5M reads/sample or 20M reads/sample; Monkeypox PE150:1.5M reads/sample or 6M reads/sample |
SE100: 4 samples(5M)/ 1 sample(20M) PE150: 16 samples(1.5M)/ 4 samples(6M) |
|||
| PE150 | Flu:~5M reads/sample | 4 samples | |||
| PE150 | HIV:~1M reads/sample | 16 samples | |||
| PE150 | TB:~3M reads/sample | 4~8 samples | |||
| Infectious Diseases identification | SE50 | 0.5M~1M reads/sample | 16~32 samples | ||
| Environmental DNA | PE150 | 65K reads/sample | 72 samples | ||
| 16S Sequencing | PE150 | ~0.3M reads/sample | 72 samples | ||
| WGS | Cultured bacteria WGS | SE100 | Single bacteria:20M reads/sample | 1 sample | |
| Bacteriophage | SE100 | ~5M reads/sample | 4 samples | ||
| Metagenomics | Pathogen Metagenomics | SE100/PE150 | Meta:20M reads/sample | 1 sample | |
| Human Genome | Target Sequencing | Education | SE100 | ~0.3M reads/sample | 48 samples |
| Forensics | SE400(Customized) | ~1M reads/sample | 10 samples | ||
| HLA | PE150 | ~2-3M reads/sample | 4-8samples | ||
| small cancer panels | PE100/PE150 | 2-5M/sample | 4 samples | ||
| Emerging field | Synthetic strand identificaton | SE100 | 0.5M~1M/sample | 24-48samples | |
| DNA storage | PE150 | 12~96 pool oligo |
System Parameters
Operating Environment Requirements
- Temperature: 15℃–30℃
- Relative Humidity: 20% RH – 80% RH
- Atmospheric Pressure: 70 kPa – 106 kPa
- Pollution Level: Level 2
* For indoor use only.
Display
- Screen: 12.1" LCD, 1280×800
- Noise: ≤65 dBA
- Protection: IPX0 (indoor)
- Storage: -20 to 50℃
Product Model
E25, E25A*
Power, Dimensions & Net Weight
- Rated Power: 25V DC, 5A
- Dimensions (W×D×H): 312 mm × 348 mm × 257 mm
- Net Weight: 15 kg
Discover More
Sequencers
Explore our cutting-edge sequencers designed for high performance and accuracy.
Customer Stories
Discover how our customers are achieving remarkable results with our technologies.
Get in Touch
Phone
📞(+86) 4000-688-114
Marketing & PR
MGI_Branding@mgi-tech.com
Careers
MGI_Recruiting@mgi-tech.com
Investor Relations
MGI_IR@mgi-tech.com