G99: Lightning-Fast, High-Precision

The G99 is one of the fastest mid-to-low throughput sequencers on the market. Engineered with innovations in biochemistry, optics, fluidics, and temperature control, it delivers rapid, high-quality results without compromise.

Designed for flexibility, the G99 supports a wide range of sequencing applications and sample volumes. With multiple flow cell options, you can tailor your run to your project needs. Achieve paired-end 150 (PE150) sequencing with Q40 accuracy in just 12 hours, dramatically reducing turnaround times and increasing lab efficiency.

Product Overview

MGI DNBSEQ-G99 ultra-fast benchtop genetic sequencer for rapid genomic workflows and mid-throughput sequencing.
DNBSEQ-G99

Performance Parameters

Max no of Flow CellsLane/ Flow CellFlow Cell TypeReads/Flow Cell*Supported Read LengthsData OutputQ30***Q40***Run Time***
21FCN20 MApp-D SE1002 Gb~4 Gb>90%>85%~2.7 h
App-D PE1506 Gb~12 Gb>90%>85%~6.7 h
App-D PE30012 Gb~24 Gb>85%>80%~18 h
FCS40 MApp-D SE1004 Gb~8 Gb>90%>85%~4 h
App-D PE15012 Gb~24 Gb>90%>85%~11 h
FCL80 MSE100/PE508 Gb~16 Gb>90%>85%~5 h
PE15024 Gb~48 Gb>90%>85%~12 h
App-D SE1008 Gb~16 Gb>90%>85%~5 h
App-D PE15024 Gb~48 Gb>90%>85%~12 h
App-D PE30048 Gb~96 Gb>85%>85%~30 h
SE40032 Gb~64 Gb>75%>70%~20 h
FCU200 MApp-D SE10020 Gb~40 Gb>90%>85%~7 h
App-D PE15060 Gb~120 Gb>85%>85%~16 h
App-D PE300120 Gb~240 Gb>85%>80%~35 h

* Effective reads is determined using a standard library. Actual output may vary depending on sample type and library preparation method.

** The percentage of bases above Q30 and run time is the average of an internal standard library over the entire run. The actual performance is affected by factors such as sample type, library quality, and insert fragment length. Only StandardMPS 2.0 (SM 2.0) reagents support the generation of Q40 data.

*** The sequencing time is the statistical duration for single flow cell sequencing and dual flow cell simultaneous sequencing.

★ The instrument is equipped with SE50 and PE100 sequencing modes, and the existing reagent kits support SE50 and PE100 read length sequencing.

Note: APP-D has built-in Illumina’s Truseq, Nextera adapters, and MGI adapter, which supporting mixed testing of Illumina’s Truseq, Nextera adapters, and MGI adapter libraries.

Method & Application Recommendations
MethodApplicationRecommended Read Length / Sample / Run
Target capture / multiplex PCROnco panel

PE100/PE150
Small panel: ~1 Gb/sample

FCN: 6/FC, 12/RUN
FCS: 12/FC, 24/RUN
FCL: 24/FC, 48/RUN
FCU: 60/FC, 120/RUN

Genetic disease diagnosis small panelDeafness

PE150
~5 Gb/sample

FCN: 1/FC, 2/RUN
FCS: 2/FC, 4/RUN
FCL: 4/FC, 8/RUN
FCU: 12/FC, 24/RUN

Thalassemia

PE150
~0.2 M reads/sample

FCN: 100/FC, 200/RUN
FCS: 200/FC, 400/RUN
FCL: 400/FC, 800/RUN
FCU: 1000/FC, 2000/RUN

ATOPlex panelRespiratory, COVID-19, etc.

PE100/PE150
5 M reads/sample

FCN: 4/FC,8/RUN
FCS: 8/FC, 16/RUN
FCL: 16/FC, 32/RUN
FCU: 40/FC, 80/RUN

WESWhole Exome SequencingPE150
15 Gb/sample
FCL: 1–2/FC, 2–4/RUN
FCU: 4/FC, 8/RUN
MethylationOnco targeted methylation panel

PE150
~5 Gb/sample

FCN: 1/FC,2/RUN
FCS: 2/FC, 4/RUN
FCL: 4/FC, 8/RUN
FCU: 12/FC, 24/RUN

Small genome sequencingMetagenomics for pathogen detection

SE50/SE100
20 M reads/sample

FCN: 1/FC,2/RUN
FCS: 2/FC, 4/RUN
FCL: 4/FC, 8/RUN
FCU: 10/FC, 20/RUN

Microbial WGS sequencing

PE100/PE150
Single bacterium:~1 Gb/sample

FCN: 6/FC,12/RUN
FCS: 12/FC, 24/RUN
FCL: 24/FC, 48/RUN
FCU: 60/FC, 120/RUN

16S sequencing

PE300
~0.1 M reads/sample

FCN: 160/FC,320/RUN
FCL: 640/FC, 1280/RUN
FCU: 1280/FC, 2560/RUN

Low-pass WGS sequencingNIPTSE50
~10 M reads/sample
FCL: 8/FC, 16/RUN
FCU: 20/FC, 40/RUN
PGSSE50

FCL: –
FCU: –
Transcriptome sequencingRNA-Seq Expression profilingSE50/PE150
~25 M reads/sample
FCL: 3/FC, 6/RUN
FCU: 8/FC, 16/RUN
TranscriptomeSE50/PE150
~6 Gb/sample
FCL: 4/FC, 8/RUN
FCU: 10/FC, 20/RUN
ForensicsDNA signature identificationSE400
~0.8 M reads/sample
FCL: 96/FC, 192/RUN
DNBSEQ-G99

System Parameters

Product Model

  • G99RS: Stable output of standard FASTQ files from 100 V to 240 V.
  • G99ARS: Equipped with a bioinformatics computing module, it can perform advanced analysis.

Power, Dimensions & Net Weight

  • Power Type: 100 V–240 V, 50/60 Hz
  • Rated Power: 1,000 VA (with a current supply of not less than 10 A)
  • Dimensions (W×D×H): 689 mm × 607 mm × 657 mm
  • Net Weight: ~140 kg
  • Maximum sound pressure level*: 75 dB(A)
  • Enclosure protection rating: IPX0

Operating Environment Requirements

  • Temperature: 15℃–30℃
  • Relative Humidity: 20% RH–80% RH, non-condensing
  • Atmospheric Pressure: 70 kPa–106 kPa
  • Maximum altitude: 3000m

*For indoor use only.

Bioinformatics Module Configurations

  • CPU: Intel Xeon 5220S 18C/36T 2.7GHz*
  • Memory: 256 GB
  • System Disk: 960 GB
  • Cache Disk: 960 GB
  • Hard Drive: 32 TB
  • Cloud Storage: Gigabit RJ45 interfaces *2

Computer Configurations

  • CPU: Intel i9-10900e 2.8 GHz
  • Memory: 64 GB
  • SSD: 5.76 TB
  • Operating System: Windows 10

* The maximum sound pressure level is measured and calculated at any position 1 metre away from the enclosure during normal operation.

** For indoor use only.

*** Supports computer configuration and system version upgrades, etc.

Discover More

Get in Touch

Email
MGI-service@mgi-tech.com

Phone
📞(+86) 4000-688-114

Marketing & PR
MGI_Branding@mgi-tech.com

Careers
MGI_Recruiting@mgi-tech.com

Investor Relations
MGI_IR@mgi-tech.com

Message us