T20×2: Ultra-High Throughput Sequencer
The T20×2 is built for the most demanding sequencing challenges. Designed for large-scale population genomics and to accelerate breakthroughs in healthcare through cutting-edge OMICS technologies, it sets a new standard in sequencing power and efficiency. This fully automated platform integrates all core components of a high-end sequencer—driven by advanced robotics—to seamlessly process up to six slides per run. It delivers outstanding performance across high-throughput applications, including whole genome sequencing (WGS), single-cell sequencing, Stereo-seq, and more.
Unavailable in the following regions: Unless otherwise stated, StandardMPS sequencing reagent is not available in: Germany, UK, Sweden and Switzerland.
Other Material
Product Overview
Performance Parameters
| Slide/Run | Effective Reads/Slide* | Supported Read Lengths | Data Output per Run | Data Quality Q30* | Run Time per Run** |
|---|---|---|---|---|---|
| 6 | 40B | PE100 | ~48 Tb | ≥85% | ~60 h |
| PE150 | ~72 Tb | ≥85% | ~80 h | ||
| *The maximum number of effective reads are based on a specific standard library. Actual results may vary depending on the sample type and library construction method. *The Q30 value is based on standard libraries; performance may vary with sample type, insert size, and library quality. **Run time includes sequencing and Cal. file generation (a binary output from MGI’s basecall software). | |||||
System Parameters
Power, Dimensions & Net Weight
- Power Type: 380/400 V, 50 Hz
- Rated Power: 20,000 VA
- Dimensions (W×D×H): 4800 mm × 4200 mm × 2000 mm
- Net Weight: 3700 kg (without BIT module)
- Floor Load Capacity: ≥500 kg/m²
Operating Environment Requirements
- Temperature: 19°C – 22°C
- Relative Humidity: 30% – 70% RH
- Atmospheric Pressure: 90 – 106 kPa
- Pollution Level: Level 2
- Indoor use only.
Usage & Installation Notes
- T20×2RS: For research use only; not for clinical diagnosis.
- Installation and maintenance by qualified personnel only.
- Install in clean, vibration-free lab with proper grounding and stable 230/400 V, 50/60 Hz power.
- Maintain temperature 19–22°C and humidity 30–70% for best performance.
Discover More
Sequencers
Explore our cutting-edge sequencers designed for high performance and accuracy.
Customer Stories
Discover how our customers are achieving remarkable results with our technologies.
Get in Touch
Phone
📞(+86) 4000-688-114
Marketing & PR
MGI_Branding@mgi-tech.com
Careers
MGI_Recruiting@mgi-tech.com
Investor Relations
MGI_IR@mgi-tech.com