The T7+ features quad-flow cell sequencing, modular reagent cartridges, and a 7-in-1 intelligent workflow covering DNB preparation and loading, sequencing, pure water and waste management, FASTQ generation, bioinformatics analysis, and integrated data compression software. With its TDI camera, ultra-high-density flow cells, ergonomic design, Omni-Smart Hub, and ZARC lossless data compression (up to 5×), the T7+ delivers speed, precision, efficiency, and intelligent automation to accelerate even the most data-intensive projects.
Other Material
Product Overview
Performance Parameters
| No. of Flow Cell per run | Flow Cell Type | Supported Read Lengths* | Reads/Flow Cell | Data Output per run | Q30*** | Run Time per run**** |
|---|---|---|---|---|---|---|
| 4 | FCL | PE75 | 11,000M | — | >90% | <14 h |
| 4 | FCL | PE100 | 12,000 M | 2.4 Tb ~ 9.6 Tb | >90% | <20 h |
| 4 | FCL | PE150 | 12,000 M | 3.6 Tb ~ 14.4 Tb | >90% | <24 h |
* The instrument is equipped with PE150, PE100 and PE75 sequencing modes, and existing reagent kits support these read lengths.
** Maximum effective reads are based on a standard library; actual yields vary by sample type and prep.
*** Percentage of bases above Q30 is averaged from standard-library runs; actual metrics depend on sample quality and insert length.
**** 24-hour run time includes DNB synthesis through .cal file generation (including automated wash).
DNBSEQ-T7+ Recommended Sample Numbers
| Application Type | Requirements | Recommended Read Length | Recommended sample numbers for a single run on T7+* | |||
|---|---|---|---|---|---|---|
| 1 FC* | 2 FC* | 3 FC* | 4 FC* | |||
| Single-cell RNA-Seq | 600 M/sample (C4: 10K cells, 50K reads/cell) | PE100 | 20 | 40 | 60 | 80 |
| Cancer large panel | 10 Gb/sample (5,000×, 1 Mb panel) | PE100/PE150 | 288 | 576 | 864 | 1,152 |
| Transcriptome | 6 Gb/sample | PE150 | 480 | 960 | 1,440 | 1,920 |
| WGS | 100 Gb/sample (30× depth) | PE150 | 28 | 56 | 84 | 112 |
| WGBS | 110 Gb/sample (30× depth) | PE150 | 24 | 48 | 72 | 96 |
| Stereo-seq (FFPE) | 3,000 M/sample | PE75 | 3 | 6 | 9 | 12 |
| Stereo-seq (FF) | 1,000 M/sample | PE75 | 12 | 24 | 36 | 48 |
* Sample numbers are calculated considering pooling variation and applications. For reference only.
DNBSEQ-T7+ Reagent Set
| Sequencing Chemistry & Workflow This sequencing set utilizes combinatorial probe anchor sequencing (cPAS) chemistry. A sequencing run starts with the hybridization of a DNA anchor, then a fluorescent probe is attached to the DNA Nanoball (DNB) using cPAS chemistry. The high-resolution imaging system captures the fluorescent signal, and after digital processing of the optical signal, the sequencer generates high-quality, high-accuracy sequencing information. Featuring a modular design for automatic mixing and multi-application auto-ID. For research use only; not for diagnostic procedures. |
| Item No. | Name |
|---|---|
| 940-002669-00 | T7+RS High-Throughput Sequencing Reagent Set (T7+ FCL PE100) |
| 940-002666-00 | T7+RS High-Throughput Sequencing Reagent Set (T7+ FCL PE150) |
| 940-002665-00 | T7+RS High-Throughput Sequencing Reagent Set (T7+ App-D FCL PE100) |
| 940-002668-00 | T7+RS High-Throughput Sequencing Reagent Set (T7+ App-D FCL PE150) |
System Parameters
Ultimate Throughput & Integration
- >14 Tb data in 24 h
- 7-in-1 smart integration: DNB M&L, sequencing, pure water container, waste container, data analysis(including FASTQ files generation and bioinformatic analysis), data compression
- Up to 35,000 WGS per year capacity
- TDI camera with ultra-high-density flow cells
- 100% throughput enhancement, 50% faster scanning
- 4 independent flow cells for flexible, high-speed sequencing
Ergonomic & Intelligent Design
- Adjustable touchscreen for ergonomic operation
- Omni-Smart Hub: One-click sequencing status overview
- Intelligent fault diagnosis & self-healing
- Smart IP assistant guides workflows
- Data loss prevention with secure checkpoint recovery
Reagents & System Handling
- Modular reagent cartridges for easy loading and replacement
- Streamlined maintenance for continuous operation
- Simplified library-to-report workflow
Power & Operating Conditions
- Power: 200–240 V~, 50/60 Hz, Rated 5000 VA
- Dimensions (W×D×H): 848 mm × 1370 mm × 1760 mm
- Net Weight: ~755 kg
- Operating Conditions:
- Temperature: 15–25 °C
- Humidity: 20–80% non-condensing RH
- Pressure: 70–106 kPa
- Transport / Storage Conditions:
- Temperature: –20–50 °C
- Humidity: 15–85% non-condensing RH
- Pressure: 70–106 kPa
Discover More
Sequencers
Explore our cutting-edge sequencers designed for high performance and accuracy.
Explore SequencersCustomer Stories
Discover how our customers are achieving remarkable results with our technologies.
Read Success StoriesGet in Touch
Phone
📞(+86) 4000-688-114
Marketing & PR
MGI_Branding@mgi-tech.com
Careers
MGI_Recruiting@mgi-tech.com
Investor Relations
MGI_IR@mgi-tech.com