DNBSEQ-E25RS High-throughput Sequencing Set

The DNBSEQ-E25RS Sequencing Set is optimized for high-performance DNA and RNA sequencing on the DNBSEQ-E25RS/ARS platform. It supports a wide range of research applications, including small genome sequencing, metagenomic studies, and targeted sequencing projects. Please note, this sequencing set is intended for research use only and is not suitable for clinical diagnostics.

Product

DNBSEQ-E25RS High-throughput Sequencing Set (FCL SE100)

Item No.: 940-000573-00

940-000570-00 DNBSEQ-E25RS High-throughput Sequencing Kit (FCL SE100)
930-000045-00 DNBSEQ-E25RS Sequencing Flow Cell

DNBSEQ-E25RS High-throughput Sequencing Set (FCL PE150)

Item No.: 940-000567-00

940-000571-00 DNBSEQ-E25RS High-throughput Sequencing Kit (FCL PE150)
930-000045-00 DNBSEQ-E25RS Sequencing Flow Cell

DNBSEQ-E25RS High-throughput Sequencing Set (App-C FCL SE100)

Item No.: 940-000569-00

940-000572-00 DNBSEQ-E25RS High-throughput Sequencing Kit (App-C FCL SE100)
930-000045-00 DNBSEQ-E25RS Sequencing Flow Cell

DNBSEQ-E25RS High-throughput Sequencing Set (App-C FCL PE150)

Item No.: 940-000574-00

940-000568-00 DNBSEQ-E25RS High-throughput Sequencing Kit (App-C FCL PE150)
930-000045-00 DNBSEQ-E25RS Sequencing Flow Cell

Product Specification

Specification SE100 PE150 App-C SE100*** App-C PE150***
Maximum flow cell number 1 1 1 1
Effective reads/flow cell* 25 M 25 M 20 M 20 M
Data output 2.5 Gb 7.5 Gb 2.0 Gb 6.0 Gb
Q30** >90% >80% >90% >80%
Run time (DNB-FQ) ~5 h ~20 h ~5 h ~20 h

* The effective reads value is obtained according to the operation of a specific standard library, and the actual application library will fluctuate according to the sample type and library construction method.
** The percentage of bases above Q30 and the running time are averaged over the entire run for a particular standard library. The practical application performance is affected by sample type, library quality, insert length and other factors.
*** The App-C Sequencing Set includes the invertase module, eliminating the need to purchase additional conversion reagents.
**** The existing kit supports SE50 and PE100 reads, and the instrument does not have SE50 and PE100 sequencing modes.

Highlights

Easy Operation

  • Load and sequence samples with a single injection—simplifying your workflow and saving valuable time.

Low-Maintenance Design

  • Reagents flow directly into the cell from the cartridge—no instrument wash needed between runs.

Streamlined Sequencing

  • One-step DNB reagents allow direct access to DNB samples, reducing preparation complexity.

Seamless Library Conversion

  • Pre-filled primers and integrated reagents support library conversion and sequencing of third-party libraries without extra purchases.

Discover More

Get in Touch

Email
MGI-service@mgi-tech.com

Phone
📞(+86) 4000-688-114

Marketing & PR
MGI_Branding@mgi-tech.com

Careers
MGI_Recruiting@mgi-tech.com

Investor Relations
MGI_IR@mgi-tech.com

Message us